  1 photoelectric sensor e3s-ls focusable sensors with built-in dc amplifiers pinpoint focusable and area focusable models eliminate background objects. ideal for precise detection of level/height, edges, small holes and openings, objects touching one another, objects inside transparent covers. ordering information sensing method sensing distance model npn output pnp output area focusable reflective 5 to 25 cm (continuously variable) e3s-ls20xe4 e3s-ls20xb4 pinpoint focusable reflective 3 to 10 cm (continuously variable) e3s-ls10xe4 e3s-ls10xb4 3 0.5 cm e3s-ls3c1d e3s-ls3rc4 --- application examples sensing of objects utilizing their difference in luster. sensing of objects traveling in contiguous succession. sensing of small holes, narrow openings, or unevenness. sensing of objects utilizing their difference in luster. sensing of objects traveling in contiguous succession. sensing of small holes, narrow openings, or evenness. pencils e3s-ls10x e3s-ls20x sensing distance supply voltage output 80 ma 100 ma 12 to 24 vdc 3 to 10 cm, 5 to 25 cm
e3s-ls e3s-ls 2 specifications ratings/characteristics item e3s-ls10x  4 e3s-ls20x  4 e3s-ls3c1d e3s-ls3rc4 power supply voltage 12 vdc ?10% to 24 vdc +10%, ripple (p-p): 10% max. 5 vdc ?10% to 24 vdc +10%, ripple (p-p): 10% max. 12 vdc ?10% to 24 vdc +10%, ripple (p-p): 10% max. current consumption 40 ma max. sensing distance 3 to 10 cm (variable with distance adjuster) 5 to 25 cm (variable with distance adjuster) 3 0.5 cm differential travel 0.5 mm max. at 3 cm 3 mm max. at 10 cm 5% max. --- standard objects 1 x 1 cm white mat paper 5 x 7.5 cm white mat paper 1 x 1 cm white mat paper control output dc solid-state load model with suffix -e4: 80 ma max. model with suffix -b4: 100 ma max. 30 ma max. 50 ma max. ou pu so dsae voltage output 1.1 v max. at 80 ma 2 v max. response time (on, off) 1 ms max. on: 3 ms off: 100 ms 1 ms max. sensitivity adjustable --- adjustable operation mode wire-selectable (refer to ?output circuit.?) --- wire-selectable (refer to ?output circuit.? ) indicators light indicator (red), stability indicator (green) operation indicator (red) light indicator (red) circuit protection short circuit mutual interference protection provided --- provided enclosure rating iec 144 ip67 ip40 nema 1, 3, 4x, 6, 12 --- housing material metal plastic light source red led infrared led red led ambient temperature operating: ?25 to 55 c operating: ?10 to 55 c
e3s-ls e3s-ls 3 engineering data excess gain ratio e3s-ls20xe4 e3s-ls10xe4 e3s-ls3rc4 excess gain ratio sensing distance (cm) excess gain ratio sensing distance (cm) excess gain ratio sensing distance (cm) peak receiver output at 3 cm peak receiver output at 5 cm peak receiver output at 10 cm note: 1. sensitivity adjustor: set to max. 2. this graph shows the relationship between the optical output and setting distance by adjusting the sensitivity adjustor so that the optical output will be maximum at a sensing distance of 3, 5, or 10 cm. operating level standard sensing object (white paper) standard sensing object (black carbon paper) operating voltage setting distance operating range e3s-ls20xe4 e3s-ls10xe4 e3s-ls3rc4 operating position y (mm) sensitivity e3s-ls20xe4 distance (cm) size of object (cm) operating position y (mm) operating position y (mm) distance: max. distance x (cm) distance: min. standard object (5 x 57.5 cm) (with minimum sensing distance) optical axis operating distance x standard object (1 1 cm) distance: 3 cm distance: 10 cm sensing object size: 10 x 10 mm setting distance (mm) short side long side white mat paper object sensed ratio of short side to long side = 2:3
e3s-ls e3s-ls 4 operation output circuits e3s-ls10x -e4 type (npn output) -b4 type (pnp output) main circuit +v output brown black blue light- on dark- on blue black brown 0 v +v brown black blue blue black brown 0 v output 2.2 ? light- on dark- on main circuit e3s-ls20x -e4 type (npn output) -b4 type (pnp output) +v output brown black blue light- on dark- on blue black brown 0 v +v brown black blue light- on dark- on blue black brown 0 v output 2.2 ? main circuit main circuit e3s-ls3c1d e3s-ls3rc4 light-on dark-on z brown black operation indicator (red) photoelectric sensor main circuit z: zener diode (v 2 = 30 v) blue brown black out blue pink photoelectric sensor main circuit incident indicator (red) brown black out photoelectric sensor main circuit incident indicator (red) blue pink +v out 0 v +v 0 v +v 0 v
e3s-ls e3s-ls 5 timing chart e3s-ls10x -e4 type (npn output) -b4 type (pnp output) light light indicator output transistor load (relay, etc.) output voltage (logic, etc.) incident interrupted on off operates releases h l on off light-on dark-on light light indicator output transistor load (relay, etc.) incident interrupted on off operates releases on off light-on dark-on e3s-ls20x -e4 type (npn output) -b4 type (pnp output) light light indicator output transistor load (relay, etc.) output voltage (logic, etc.) incident interrupted on off operates releases h l on off light-on dark-on light light indicator output transistor load (relay, etc.) incident interrupted on off operates releases on off light-on dark-on e3s-ls3c1d e3s-ls3rc4 sensing object yes no indicator on off on off timer setting output transistor (load) 3 ms max. < t (see note) t (see note) note: timer setting t = 0.1 to 1 s (between brown and black lines) light light indicator output transistor load (relay, etc.) incident interrupted on off operates releases on off light-on dark-on
e3s-ls e3s-ls 6 dimensions note: all units are in millimeters unless otherwise indicated. e3s-ls10x  4 e3s-ls20x  4 cord: 4-mm dia., 18/0.12, 3-conductor standard length: 2 m weight: approx. 225 g note: a mounting bracket can be attached to side a. sensitivity adjustor distance adjustor 8 dia. indicator emitter receiver two, m4 slotted hexagonal bolts lens (14 x 47) (a) (see note) optical axis two 4.4 dia. holes two, m 4 holes 20 mounting holes e3s-ls3c1d e3s-ls3rc4 cord: 4-mm dia., 18/0.12, 3-conductor standard length: 2 m weight: approx. 60 g indicator e3s-ls3c1d timer volume e3s-ls3rc4 sensitivity adjustor 8 dia. optical axis optical axis two, m3 holes
e3s-ls e3s-ls 7 precautions sensing distance adjustment e3s-ls10xe4 adjustment method 1. set the pointer of the sensitivity adjuster to the center of its revolution range. 2. turn the distance adjuster fully counterclockwise to the ?s? position. 3. set the sensing object in position. 4. turn the distance adjuster gradually clockwise to a point where both the light and st ability indicators light. fix the distance adjuster at that point. 5. adjust sensitivity. distance adjuster object sensed background object e3s-ls20xe4 adjustment method 1 when the quantity of light reflected from the object is greater than that from the background object, adjust the sensing distance in the following sequence: 1. set the pointer of the sensitivity adjuster to the center of its revolution range. 2. turn the distance adjuster fully counterclockwise to the ?s? position. 3. set the sensing object in position. 4. turn the distance adjuster gradually clockwise to a point where both the light and st ability indicators light. fix the distance adjuster at that point. 5. adjust sensitivity. distance adjuster object sensed background object adjustment method 2 when the quantity of light reflected from the object is greater than that from the background object, adjust the sensing distance in the following sequence: 1. set the pointer of the sensitivity adjuster to the center of its revolution range. 2. turn the distance adjuster fully counterclockwise to the ?l? position. 3. remove the sending object. 4. turn the distance adjuster gradually clockwise to a point where both the light and st ability indicators light. fix the distance adjuster at that point. 5. adjust sensitivity.
2007. 3 omron corporation industrial automation company http://www.ia.omron.com/ (c)copyright omron corporation 2007 all rights reserved. in the interest of product improvement, specifications are subject to change without notice. read and understand this catalog please read and understand this catalog before purchasing the products. please consult your omron representative if you have any questions or comments. warranty and limitations of liability warranty omron's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifed) from date of sale by omron. omron makes no warranty or representation, express or implied, regarding non-infringement, merchantability, or fitness for particular purpose of the products. any buyer or user acknowledges that the buyer or user alone has determined that the products will suitably meet the requirements of their intended use. omron disclaims all other warranties, express or implied. limitations of liability omron shall not be responsible for special, indirect, or consequential damages, loss of profits, or commercial loss in any way connected with the products, whether such claim is based on contract, warranty, negligence, or strict liability. in no event shall responsibility of omron for any act exceed the individual price of the product on which liability is asserted. in no event shall omron be responsible for warranty, repair, or other claims regarding the products unless omron's analysis confirms that the products were properly handled, stored, installed, and maintained and not subject to contamination, abuse, misuse, or inappropriate modification or repair. application considerations suitability for use omron shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. at the customer's request, omron will provide applicable third party certifcation documents identifying ratings and limitations of use that apply to the products. this information by itself is not suffcient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. the following are some examples of applications for which particular attention must be given. this is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: ? outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. ? nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. ? systems, machines, and equipment that could present a risk to life or property. please know and observe all prohibitions of use applicable to the products. never use the products for an application involving serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the omron product is properly rated and installed for the intended use within the overall equipment or system. disclaimers change in specifications product specifcations and accessories may be changed at any time based on improvements and other reasons. it is our practice to change model numbers when published ratings or features are changed, or when signifcant construction changes are made. however, some specifcations of the product may be changed without any notice. when in doubt, special model numbers may be assigned to fx or establish key specifcations for your application on your request. please consult with your omron representative at any time to confrm actual specifcations of purchased product. dimensions and weights dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. errors and omissions the information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. performance data performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. it may represent the result of omrons test conditions, and the users must correlate it to actual application requirements. actual performance is subject to the omron warranty and limitations of liability. programmable products omron shall not be responsible for the user's programming of a programmable product, or any consequence thereof. copyright and copy permission this catalog shall not be copied for sales or promotions without permission. this catalog is protected by copyright and is intended solely for use in conjunction with the product. please notify us before copying or reproducing this catalog in any manner, for any other purpose. if copying or transmitting this catalog to another, please copy or transmit it in its entirety. cat. no. e39-e1-3


▲Up To Search▲   

 
Price & Availability of E3SLS10XE4

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X